Product Range

ANAESTHESIA RANGE OF PRODUCTS & ITS ACCESSORIES AUTOCLAVE HOSPITAL HOLLOWARE SUCTION UNITS BABY CARE RUBBER GOODS HOSPITAL FURNITURE SCALES DIAGNOSTIC REHABILITATION AIDS MEDICAL DISPOSABLES HISTOPATHOLOGY LAUNDRY EQUIPMENT OPHTHALMIC INSTRUMENTS BLOOD PRESSURE & PULSE MEASUREMENT MEDICAL EQUIPMENT NON WOVEN SURGICAL INSTRUMENTS VACCUTAINERS TUBE NEBULIZER DELIVERY SET MEDICAL PAPER DIATHERMY MACHINES MEDICAL LIGHT POLYGLACTIN SUTURE ELEECTROLYTE ANALYZER MEDICAL BANDAGES MEDICAL COTTON TESTING EQUIPMENT

OXYGEN THERAPY EQUIPMENTS


CLM AN OTE 1198 HUMIDIFIER WITH RELIEF VALVE

HUMIDIFIER WITH RELIEF VALVE  

CLM/AN/OTE/HU/1198 -  Humidifier - screw on type 

CLM/AN/OTE/HU/1199 - Humidifier - for generator

Brass chrome plated lnlet & Outlet

Oxygne Humidifier provides highhumidity to oxygen using the

bubble- type humidification process. it contains a 3 - psi safety relief valve.

the outlet fitting is a huse barb for 6mm id plastic tubing. max. and min.

water levels are clearly marked; the max line holds 100 ml of water 


CLM AN OTE FU 1177 MEDICAL OXYGEN REGULATOR

MEDICAL OXYGEN REGULATOR               

Technical Specification of

Input pressure:15Mpa/23Mpa
Output pressure:0.2-0.3Mpa
Automatic discharge pressure of the safety valve:0.35+_0.05Mpa
The range of flow: 0-10/15L/min
Connection thread: G5/8 Female,CGA540/W21.8 (to be Confirmed by Customer)
Humidifier connection:M12*1
Plastic Guage Guard to protect the gauge(optional )
Inlet connection nut with handwheel for easy connection(optional)
Mainbody:brass
Structure:PISTON type  Pre-set outlet pressure:2-3bar
Humidifier bottle:200ML
Packing :10PCS/CTN (color box)
G.W./N.W.:12/11KGS

Dimension:52×44×18cm                         


CLM AN OTE HU 1200 HUMIDIFIER WITH RELIEF VALVE PLASTIC

HUMIDIFIER WITH RELIEF VALVE PLASTIC 

CLM/ANOTE/HU/1200 - Humidifier - for generator


CLM AN OTE OR 1175 OXYGEN REGULATOR WITH FLOW GAUGE

OXYGEN REGULATOR WITH FLOW GAUGE
Replacement of the flowmeter unit by a Flow Gauge with Gauge Saver and a
rugged all metal construction ensures less frequent & reduced maintenance /
servicing. Tamper-proof Safety Blow off situated inside the regulator prevents
unauthorized adjustment of blow off pressure Larger Control Knob provides
more convenient
operation.

CLM AN OTE OR 1176 OXYGEN REGULATOR

OXYGEN REGULATOR
The Regulator has a factory preset fixed static outlet pressure of approx. 4.2 Kg/
Sq.cm (60 lbs/sqin) and is fitted with safety valve. Once the flowrate has been
set, the regulator will automatically maintain a constant flow rate irrespective of
changing volume of cylinder contents. If the oxygen line distal to the
regulator should be blocked, the regulator automatically prevents the build up
of an excessive pressure in the apparatus and tubing between the outlet of the
regulator and the obstruction. A pressure gauge indicates the cylinder contents.

CLM AN OTE OR 1178 TWO STAGE OXYGEN REGULATOR

TWO STAGE OXYGEN REGULATOR
Two Stage Regulator it has two diaphragms where by provides extra safety in
case of damage to one of the
diaphragm. It has an Extra Gauge to indicate outlet pressure.

CLM AN OTE FU 1190 FLOWMETER UNIT

FLOWMETER UNIT
Metal and Plastic
The Back Pressure Compensated (BPC) flowmeter incorporates a rotary pin
valve control to permit adjustment of the flow rate to any desired level between
0 - 15 ltrs/min. Jacketed type shatterproof tubes are fitted on the units The outlet
at the bottom of the unit is fitted with a removable nipple. After removing the
outlet nipple, a humidifier can be screwed into the outlet of the flowmeter unit.
Flow accuracy is unaffected by back pressure due to down stream restrictions
caused by humidifiers, nebulizers etc.

CLM AN OTE FU 1179 F A FINE ADJUSTMENT VALVE WITH GUAGE FLOWMETER

 F/A (FINE ADJUSTMENT) VALVE WITH GUAGE & FLOWMETER
Set comprises of F/A Valve with Gauge, Flowmeter & Gauge Saver the unit reduces the
cylinder pressure by merely providing a variable restriction to the flow of Oxygen from
the cylinder outlet. As volume of Oxygen in the cylinder reduces, the flowmeter has to be
constantly adjusted to maintain the required flowrate. The flowmeter unit without control is
fitted with jacketed type shatter proof tubes calibrated from 0-15ltrs/min.
Note : The flowmeter without control used in the F/A Valve should not be used with an
Oxygen Regulator.

CLM AN OTE HU 1195 HUMIDIFIERS

HUMIDIFIERS
Consists of an unbreakable jar with screw on cap fitted on top
inlet and side outlet tubes. The inlet tube ends in a specially
designed diffuser from which oxygen is bubbled through water
before reaching the outlet.
CLM/AN/OTE/HU/1195 - Humidifier with “S” Hook - for hanging
on the cylinder trolley or flowmeter unit.
CLM/AN/OTE/HU/1196 - Humidifier - screw on type - Plastic Inlet
Provided with 1/2” BSF threads that can be screwed on directly
to the outlet of the flowmeter.
CLM/AN/OTE/HU/1197 - Humidifier - for generator - Plastic Inlet
Has a 9/16 UNF female knurled nut & nipple at the inlet.

CLM AN OTE 1191 VENTILATOR FOR BRONCHOSCOPY

VENTILATOR FOR BRONCHOSCOPY
A ventilating system for rigid wall bronchoscopy and laryngeal microsurgery.
Comprises : 2mtrs. High Pressure Tubing, Thumb Valve Control and three Luer
Lock Needles.

CLM AN OTE OR 1180 TWIN GAUGE OXYGEN REGULATOR

 TWIN GAUGE OXYGEN REGULATOR
Specially introduced for use with the Jet Ventilator and other applications, it has
an extra gauge to indicate the outlet pressure of the regulator and incorporates
a safety valve. The outlet pressure can be adjusted with the help of the key to
desired value depending upon use for Paediatric or Adult patients.

CLM AN OTE OR 1181 AIR REGULATOR

AIR REGULATOR

The Regulator has a factory preset fixed staticoutlet pressure of approx. 4.2 kg/sq.cm and is fitted with safety valve. Once the flow rate has been set. the regulator will automatically maintain a constant flow rate irrespective of changing volume of cylinder containt. A pressure gauge indicates the cylinder containts.


CLM AN OTE OR 1182 NITROUS OXIDE REGULATOR

NITROUS OXIDE REGULATOR
Nitrous Oxide Regulators have bright chrome plated forged brass body that
ensures long life and corrosion resistance of these products.
Technical Details:
• 2” diameter gauge with gauge guard
• Factory preset at 4.2 kg/cm
• Built in safety valve to protect against over pressurization
• Durable neoprene diaphragm

CLM AN OTE 1183 ACC TWIN FLOWMETER ADAPTOR

TWIN FLOWMETER ADAPTOR

For using two BPC flowmeters from one oxygen regulator.


CLM AN OTE 1184 ACC SPANNERS KEYS

SPANNERS & KEYS
Combination Key & Spanner - For fitting Regulators & F/A Valves onto Cylinders
and for opening Bull Nose type Cylinders. Cannot be used to open Pin Index
type Cylinders CLM/AN/OTE/1184-ACC.
Multipurpose - For fitting flowmeters onto F/A Valves or Regulators, Hex Nuts
onto Bull Nose type & Flush type Cylinders & for opening and closing both Bull
Nose type as well as Pin Index type Cylinders CLM/AN/OTE/1185-ACC.
Key for Pin Index Cylinders - For opening Pin Index type Cylinders & fitting Hex
Nuts to the valves CLM/AN/OTE/1186-ACC.

CLM AN OTE 1210 OXYGEN NASAL CANNULA DISPOSABLE

OXYGEN NASAL CANNULA DISPOSABLE 
Adult
Child
Neonatal
Not just another oxygen nasal cannula - the ‘U’ shaped moulding with limbs
which is inserted into the nostrils will not hurt the patient when inserted.
Extremely light in weight, the nasal tips ensure a comfortable fit for efficient
oxygen therapy. Supplied with 2 meters tubing.

CLM AN OTE 1211 OXYGEN MASK PLAIN DISPOSABLE

OXYGEN MASK - PLAIN (DISPOSABLE)
Adult
Child
Light weight design, soft feathered edges for increased patient comfort, nose
clip for nose bridge adjustment & for better fit, pull through adjustable elastic
head band & swivel tubing connector for changing angle of operation without
disturbing the mask.

CLM AN OTE 1212 OXYGEN MASK WITH CONTROL DISPOSABLE

OXYGEN MASK WITH CONTROL DISPOSABLE 
Adult
Child
One piece adjustable venturi valve with a choice of seven oxygen percentage
settings (24, 26, 28, 31, 35, 40 & 45%) allowing the concentration of oxygen
delivered to the patient to be set and changed as clinically as is required.
Eliminates use of several selector venturi valves thus significantly reducing the
time required to change oxygen concentrations.

CLM AN OTE 1213 HIGH CONCENTRATION MASK DISPOSABLE

HIGH CONCENTRATION MASK (DISPOSABLE)
Adult
Child
High concentration Oxygen Mask is used to deliver 100% Oxygen to patient.
There is a two litre reservoir bag with 3 one-way valves to deliver 100% Oxygen.
Two expiratory valves are easily detachable as per the need of the patients.

CLM AN OTE 1214 OXYGEN MASK WITH NEBULISER DISPOSABLE

OXYGEN MASK WITH NEBULISER DISPOSABLE 
Adult
Child
Set comprises of plain Oxygen Mask, Nebuliser Jar & tubing. The nebuliser jar is
specially designed for the delivery of drugs for tracheobronchial deposition. At
gas flow of 8 L/min, 70% of output will be particles of less then 5 microns.

CLM AN OTE 1215 NEBULISER MOUTH KIT

NEBULISER MOUTH KIT
Mouthpiece is particularly useful for patients who can coordinate their breathing
for drug delivery, thereby increasing the amount of aerosol reaching the lungs.

© 2017 CARELABMED. All rights reserved. Creation of SstDesigns