ANAESTHESIA RANGE OF PRODUCTS & ITS ACCESSORIES AUTOCLAVE HOSPITAL HOLLOWARE SUCTION UNITS BABY CARE RUBBER GOODS HOSPITAL FURNITURE SCALES DIAGNOSTIC REHABILITATION AIDS MEDICAL DISPOSABLES HISTOPATHOLOGY LAUNDRY EQUIPMENT OPHTHALMIC INSTRUMENTS BLOOD PRESSURE & PULSE MEASUREMENT MEDICAL EQUIPMENT NON WOVEN SURGICAL INSTRUMENTS VACCUTAINERS TUBE NEBULIZER DELIVERY SET MEDICAL PAPER DIATHERMY MACHINES MEDICAL LIGHT POLYGLACTIN SUTURE ELEECTROLYTE ANALYZER MEDICAL BANDAGES MEDICAL COTTON TESTING EQUIPMENT

CARELABMED DIATHERMY MACHINES


CLM 01 FAST SEALING SYSTEM DIGITAL ELECTRO SURGICAL GENERATOR WITH VESSEL SEALING SYSTEM

DIGITAL ELECTRO SURGICAL GENERATOR WITH VESSEL SEALING SYSTEM

 

Max. power (Watts)

Rated Load (Ohms)

Operating frequency

1mhz

-

Display

FND Display

-

Pure cut

400W

500

Blend 1

300W

500

Blend 2

250W

500

Endocut

100W

500

coagulation

Spray

150W

500

Fulguration

200W

500

Desiccation/soft.

100W

500

Bipolar

Bipolar coagulation micro

99W

500

Bipolar coagulation micro

60W

500

Bipolar coagulation Dissecting

40W

500

Sealing capability

75 gsm to 5 mm

100

Dimension (W x H x D)

12” x 14” x 4.5”

100

Weight

5.0 kg

100

Input Voltage

150 to 260 VAC 50 Hz

500

 


CLM 02 DIGITAL SURGICAL CAUTTRY 400 WATT WITH UNDER WATER CUTTING

DIGITAL  SURGICAL  CAUTTRY 400 WATT WITH UNDER WATER CUTTING

 

 

Max. power (Watts)

Rated Load (Ohms)

Operating frequency

1mhz

-

Display

FND Display

-

Pure cut

400W

500

Blend 1

300W

500

Blend 2

250W

500

Endocut

100W

500

coagulation

Spray

150W

500

Fulguration

200W

500

Desiccation/soft.

100W

500

Bipolar

Bipolar coagulation micro

99W

100

Bipolar coagulation micro

60W

100

Bipolar coagulation Dissecting

40W

100

Dimension (W x H x D)

12” x 14” x 4.5”

 

Weight

5.0 kg

 

Input Voltage

150 to 260 VAC 50 Hz

 

 


CLM 03 DIGITAL SURGICAL CAUTTRY 400 WATT WITH UNDER WATER CUTTING

DIGITAL  SURGICAL  CAUTTRY 400 WATT WITH UNDER WATER CUTTING

 

Max. power (Watts)

Rated Load (Ohms)

Operating frequency

1mhz

-

Display

FND Display

-

Pure cut

400W

500

Blend 1

300W

500

Blend 2

250W

500

Endocut

100W

500

coagulation

Spray

150W

500

Fulguration

200W

500

Desiccation/soft.

100W

500

Bipolar

Bipolar coagulation micro

99W

100

Bipolar coagulation micro

60W

100

Bipolar coagulation Dissecting

40W

100

Dimension (W x H x D)

12” x 8” x 4.5”

 

Weight

3.0 kg

 

Input Voltage

110 to 260 VAC 50 Hz

 

 


CLM 04 NON DIGITAL ELECTRO SURGICAL DEVICE 400W

NON DIGITAL ELECTRO SURGICAL DEVICE – 400W

 

Max. power (Watts)

Rated Load (Ohms)

Operating frequency

480mhz

-

Pure cut

400W

500

Blend 1

300W

500

Blend 2

250W

500

Endocut

100W

500

coagulation

Spray

150W

500

Fulguration

200W

500

Desiccation/soft.

100W

500

Bipolar

Bipolar coagulation micro

99W

100

Bipolar coagulation micro

60W

100

Bipolar coagulation Dissecting

40W

100

Dimension (W x H x D)

12” x 14” x 4.5”

 

Weight

3.0 kg

 

Input Voltage

150 to 260 VAC 50 Hz

 

 


CLM 05 DIGITAL ELECTRO SURGICAL DEVICE 300W

DIGITAL ELECTRO SURGICAL DEVICE – 300W

 

Max. power (Watts)

Rated Load (Ohms)

Operating frequency

1mhz

-

Display

FND Display

-

Pure cut

400W

500

Blend 1

300W

500

Blend 2

250W

500

Endocut

100W

500

coagulation

Spray

150W

500

Fulguration

200W

500

Desiccation/soft.

100W

500

Bipolar

Bipolar coagulation micro

99W

100

Bipolar coagulation micro

60W

100

Bipolar coagulation Dissecting

40W

100

Dimension (W x H x D)

12” x 14” x 4.5”

 

Weight

3.0 kg

 

Input Voltage

150 to 260 VAC 50 Hz

 

 


CLM 06 ELECTRO SURGICAL DEVICE 100W

ELECTRO SURGICAL DEVICE – 100W

Power – 100W              Model - Digital

Programmable             Capability – All Surgeries

Excellent quality          Hight Frequency Device

 

 

Max. power (Watts)

Rated Load (Ohms)

Operating frequency

480mhz

-

Pure cut

400W

500

Blend 1

300W

500

Blend 2

250W

500

Endocut

100W

500

coagulation

Spray

150W

500

Fulguration

200W

500

Desiccation/soft.

100W

500

Bipolar

Bipolar coagulation micro

99W

100

Bipolar coagulation micro

60W

100

Bipolar coagulation Dissecting

40W

100

Dimension (W x H x D)

12” x 14” x 4.5”

 

Weight

3.0 kg

 

Input Voltage

150 to 260 VAC 50 Hz

 

 

 


CLM 07 RF CAUTRY

RF CAUTRY

The technique of radio surgery involves the passage of high frequency radiwaves  (2mhz-megahertz) through soft tissue to cut, coagulate, or remove the tissue. Soft tissue resistance to these radio waves causes the cellular water in the soft tissue to heat, which produces steam, an results in cellular molecular dissolution of individual tissue cells.

The surgeon uses a hand piece with an active electrode (different type of electrodes for applications) to transmit the radio waves. The radio waves are focused on the tissue by an antenna plate ( Patient plate ) that is positioned behind the tissue in contact with patient’s  skin.

Radio surgery  in general practice has many advantages over conventional surgical techniques particularly dermatological, plastic and eye lid surgery. ENT, Dental, quicker operating time rapid healing, less tissue damage and less post operative discomfort have been observed and its wider se in hospital practice is recommended.

SPECIFICATION

Power input 220 volts +-5%

Power consumption 150 watts

Frequency 2 MHZ

Maximum output

HF Monopolar 150 watts on 400 ohm load-HF bipolar 100 watts on 100 ohm load

Fulguration 100 watts on 1000 ohm.


CLM 08 RF CAUTRY

RF CAUTRY

The technique of Radio surgery involves the passage of high frequency radio waves (2mhz-megahertz)through soft tissue to cut, coagulate, or remove the tissue. Soft tissue resistance to these radio waves causes the cellular water in the soft tissue radio waves causes the cellular water in the soft tissue to heat, which produces steam, an results in cellular molecular dissolution of individual tissue cells.

The surgeon uses a hand piece with an active electrode (different type of electrodes for different applications)to transmit the radio waves. The radio waves are focused on the tissue by an antenna plate (patient plate) that is positioned behind the tissue in contact with patient’s skin.

Radio surgery in general practice has many advantages over  conventional surgical techniques particularly dermatological, plastic and eye lid surgery. ENT,Dental, quicker operating time apid healing, less tissue damage and less post operative discomfort have been observed and its wider use in hospital practice is recommended.

SPECIFICATION

Power input 220 volts +-5%

Power consumption 150 watts

Frequency 2 MHZ

Maximum output

HF monopolar 150 watts on 400 ohm load

HF bipolar 100 watts on 100 ohm load

Fulguration 100 watts on 1000 ohm.


CLM 09 THERMAL CAUTTRY

THERMAL CAUTTRY

FEATURES

  • 6FT. cord
  • Long battery life
  • 24 gauge olatinum wire

BENEFITS

  • No site burns
  • Stable temperature

APPLICATIONS

  • Any surgical procedure

Traditional thermal cauttry utilizes heat in the form of direct current to perform coagulation. This method eliminates the possibility of alternate site burns that can occur with electrosurgery. Only the heated wire tip comes in contact with the tissue and current does not enter the patient’s body thermal cauttry unit provides all the cauttry power necessary for treating numerous minor surgical conditions and is ideal for applications such as dermatological, ophthalmological occupational health, ENT, and plastic surgery cases, or any procedure that requires accurate hemostasis.

The thermal cauttry unit maintains the desired temperature during tissue contact and does not rapidly diminish like disposable battery powered cauteries. The autoclavable hand piece with six-foot cord accepts an assortment of reusable thermal cauttry electrodes, allowing the surgeon to have the flexibility to perform a wide variety of procedures. This unit will outlast battery-powered unit and save money on replacement batteries.

Reusable electrodes have solid 1-inch brass shanks : tips are made with 24 gauge platinum wire. These general purpose electrodes are supplied non-sterile, but may be autoclaved.

CLM DESCRIPTION

  501295

Loop tip general purpose electrode, included

  501296

Fine tip general purpose electrode

  501297

Loop tip angled general purpose electrode, included

  501298

  Ball tip general purpose electrode

  501299

  Fine tip general purpose electrode, included

  504034

  Circular tip general purpose electrode, included

  503299

  Vasectomy tip electrode

  504035

  Loop tip bent perpendicular general purpose electrode

  504036

  Fine tip bent perpendicular general purpose electrode

TECHNICAL SPECIFICATION

Line voltage

110/220 V,60HZ/50HZ

Output wave shape

Clipped sinusoidal

Output power

0 -30 watts ± 6  watts (0.2 OHM load)

Maximum output power

36 watts (0.2OHM load)

dimensions

13cm x 13cmx20cm (dxwxh)

Shipping weight

5lb.(2.3kg)

 


CLM 10 APNEA MONITOR

APNEA MONITOR

HEALTH PROBLEM ADDRESSED

Apnea monitors detect the cessation of breathing (apnea) in infants and adults who are risk of respiratory failure and alert the parent or attendant to the condition, some prolonged respiratory pauses result in low oxygen concentration levels in the body. Which can lead to irreversible brain damage and. If prolonged. Death.

PRODUCT DESCRIPTION

The components of apnea monitors depend specifically in the type. However, in general they are composed of a set of sensors which obtain the information of different physiological parameters. This information is passed to a micro computer system, which analyes the sensors information and determines if apnea is occurring.

PRINCIPALES OF OPERATION

Monitors that use impedance penumography detect small changes in electrical impedance as air enters and leaves he lungs and as the blood volume changes in the thoracic cavity. Mattress-type motion sensors typically monitor changes in the capacitance or resistance of matters transducer. Pneumatic abdominal sensors, thmistors, proximal airway pressure sensors, carbon dioxide (co2) sensors, cannula) once connected, as the patient breathes, the unit monitors different body parmeters. If an alarm sounds, operators must attend the patient immediately.

REPORTED PROBLEMS

Apnea monitors may fail to alarm during an episode because they sense artifact (artifacts include vibration, heart activity, patient movement) electromagnetic emissions from electronic devices (other electronics or equipment) can also cause interference. Possibly leading to false breath and heartbest detection, impedance anemographs are more subjects to cardiovascular artifact. Misinterpreting impedance change because of heartbeats perceived as breath frequent when instrument sensitivity is not adjusted.

USE AND MAITNATENANCE

User(s): Nurse, medical staff, home care providers maintenance e: Biomedical or clinical engineer/technician, medical staff, manufacturer/servicer Training: initial training by manufacturer, operator;s manuals user’s guide

ENVIRONMENT OF USE

Setting of use: hospital, home, ambulatory care center, nursery

Requirements: uninterruptible power source, battery backup

PRODUCT SPECIFICATION

Approx. dimension (mm): 150x120x120

Approx. wight (kg):0.75

Consumables: batteries, cables, electrodes/sensors

Typical product life time (year):8

Shelf life (consumables):NA

TYPES AND VARIATIONS

Stand –alone, modular


CLM 11 DIGITAL FETAL ADULT MULTIPLE HEART BEAT MONITOR DEVICE

DIGITAL FETAL& ADULT MULTIPLE HEART BEAT MONITOR DEVICE

Our range of digital fetal heart beat monitors, works on the principle of Doppler’s effect. We have incorporated a very low intensity ultrasonic frequency of 2.23 MHZ beamed into the body from a probe and it is reflected back from the organs and blood particles. Further the frequency of reflected signal is changed slightly due to movement of fetal heart blood particles and other moving organs. Then the reflected signal received by the instrument is amplified and processed electronically to get audible signal through built in speaker or external earphone.

Some of the sailent features of our products are as follow:

  1. Operating probe frequency 2.23 MHz for Observation in gynecology field.
  2. Power main and rechargeable inbuilt battery operated,
  3. High & low alarm indication
  4. Beat hold facility
  5. Speaker/ear phone facility
  6. Digital display fetal heart beat
  7. To read the Volume level.
  8. Round the clock monitoring systems.
  9. Individual fatal and adult mode of operation.

The specification of our product are as follow.

  1. Voltage : 240 VAC 50 Hz
  2. Frequency : 2.23 MHZ
  3. Input : 9 Volt DC
  4. Battery : 1.2AH 12 Volt DC
  5. Absorbed power : 9 Volt DC
  6. Audio output power : 4 watts

CLM 12 DIGITAL FETAL ADULT MULTIPLE HEART BEAT MONITOR DEVICE

DIGITAL FETAL & ADULT MULTIPLE HEART BEAT  MONITOR DEVICE

Our range of digital feta heart beat monitor, work on the principle of Doppler’s effect. We have incorporated a very low intensity ultrasonic frequency of 2 MHZ beamed into the body from a probe and it is reflected back from the organs and blood particles. Further the frequency of reflected back from the organs and blood particles. Further the frequency of reflected signal is changed slightly due to movement of fetal heart blood particles and other moving organs. Then then reflected signal received by the instrument is amplified and processed electronically to get audible signal through built in speaker or external earphone.

  1. Operating probe frequency 2 MHz for Observation in gynecology field.
  2. Power mains and rechargeable inbuilt battery operated,
  3. High & low alarm indications,
  4. Beat hold facility
  5. Digital fetal heart beat.
  6. Speaker/ear phone facility
  7. To read the Volume level.
  8. Round the clock monitoring system.
  9. Individual fetal and adult mode of operation

The specifications of our products are as follows :

  1. Voltage : 240 V AC 50 Hz
  2. Frequency : 2 MHz
  3. Input  : 9 volt DC
  4. Battery : 1.2AH 12 Volt DC
  5. Absorved power : 9 Volt DC
  6. Audio output power : 4 watts

CLM 13 NEOCARE COMPACT ULTRASONIC DOPPLER

NEOCARE COMPACT ULTRASONIC DOPPLER

FEATURES

  1. Compact Li-ion Battery & DC adapter
  2. Built –in Audio Recorder
  3. Interchangeable water proof Probe

ADDITIONAL FEATURES INCLUDE:

  1. Accurate FHR detection with clear sound
  2. Supports 2.23MHz,
  3. Manual FHR counting
  4. Up to four hours of continuous use

SPECIFICATION

  1. Heart rate range : 50~210 bpm audible
  2. Resolution : 1 bpm
  3. Audio sampling g frequency : 4KHz/ 8 KHz
  4. Audio output power : 0.5W
  5. Size : 32 mm (D) x 85 mm (W) x138 mm (H)
  6. Weight: 290±5g (includes one battery) 

CLM 14 FETAL MONITOR WITH TOCOGRAPH

FETAL MONITOR WITH TOCOGRAPH 

Fetal heart rate (FHR), uterus constriction (TOCO) and fetal movement (FM)

5.7 inches blue background LCD screen with high resolution and luminance

Recording all the parameters in graphic tendency curves as well as numeric data

Alarm on probe off-position, abnormal FHR.adjustable FHR alarming system

Built-in thermal printer with 3-grade (1,2 and 3 cm/min)tracing speed

Built –in network connection capability

Twins monitoring function (option)

TECHNICAL SPECIFICATION

  1. Compact and light weight
  2. Should have function if-
  1. Fetal heart rate recording (basal heart rate. Short Term Variation, high and low variation. Acceleration and deceleration, signal loss, contraction and feral movement)
  2. Toco recording (for intra uterine pressure recording) c.) maternally sensed fetal movement recording
  1. Illuminated graphical display should show on screen FHR and Toco traces
  2. Should have twin monitoring and its analysis facility
  3. Annotation of patient name. gestation period .reference no. and hospital name
  4. Automatic of patient name. gestation period, recording of fetal movement
  5. 1.17 MHz ultrasound transducers
  6. External Toco transducers
  7. Detachable printer
  8. patient event marker
  9. minimum five hours memory tracing and fast print facility.
  10. Dual channel twin printout facility
  11. Display waveform and digital.
  12. Purpose designed trolley/cart.
  13. Built in rechargeable battery backup (minimum two hours)
  14. Selectable chart speed 1/2/3 cm/min.
  15. Should have interconnecting cabbies. Lycra transducer be its. Belt buckles, mains cable. Ultrasonic gel bottles. Pack of pre printed graph paper (minimum sis in no.) and operating manual.