CLM 1203 MULTI CHANNEL DIGITAL ECG MACHINE WITH MEASUREMENT INTERPRETATION SINGLE SINGLE R THREE CHANNEL
MULTI-CHANNEL DIGITAL ECG MACHINE WITH MEASUREMENT & INTERPRETATION SINGLE , SINGLE + R & THREE CHANNEL
-
Single, single + R & 3 channel print
-
Auto, manual, analysis, Arrethym& Trend Mode
-
Simultaneous 12-lead acqunition
-
1 selectable Rhythm lead display on screen
-
Built on thermal printer (54 mm paper size)
-
Lightweight, 2.5 kg inclusive of battery.
-
Built-in rechargeable battery (backup 3-4 Hrs)
-
Complete digital filter to avoid baseline drifting and interfering from AC, EMG
-
Grid printing (selectable)
SPECIFICATION…
Lead
|
Standard 12 leads
|
Recording Channel
|
3 channel, Single & Channel +R
|
Rhythm Lead
|
Manually Selectable
|
Arrhy Lead
|
Manually selectable
|
Data acquisition
|
18bit / 1000Hz
|
Record Mode
|
Manual automatic, analysis &Trend Mode
|
Filter
|
A.C, LP, Muscle ,EMG, Drift Filter’
|
Input Circuit
|
Floating; Protection against Defibrillator & Pacemaker
|
Auditory Alarm
|
Yes
|
Input Impedence =
|
5.0MO
|
Time constant >
|
3.2s
|
Time Constant >
|
3.2s
|
Auto rec time
|
2.5, 5, 10, 20 S
|
Frequency Response
|
0.05~150Hz
|
Noisy Level =
|
15µV
|
Sensitivity valve =
|
20µV
|
Inter-Channel Interference =
|
0.5mm
|
Paper speed
|
5.0, 10.0,12.5, 25 / 50mm/s
|
Sensitivity
|
AUTO, 2,5,5,10,20mm/mV
|
Recording mode
|
Thermal Array printing
|
Paper Specification
|
50mmx20m, roll
|
LCD Display
|
20×2 character LCD, display status
|
Safety classification
|
IEC60601-1 class 1, type CF
|
Power supply AC
|
110V/220v/85~265V,50/60Hz±1Hz;30VA
|
DC:
|
12V(1500mAh)rechargeable battery
|
CLM 1206i MULTI CHANNEL DIGITAL ECG MACHINE THREE THREE R SIX CHANNEL WITH INTERPRETATION COMPUTER CONNECTIVITY
MULTI –CHANNEL DIGITAL ECG MACHINE THREE, THREE + R& SIX CHANNEL WITH INTERPRETATION & COMPUTER CONNECTIVITY
-
Three channel, three channel + R & six channel print
-
1 selectable Rhythm lead display on screen
-
Built in thermal printer (110 mm paper size)
-
Simultaneous 12-lead acqunition
-
Automatic and manual recording modes
-
Lightweight, 2.5 kg inclusive of battery.
-
Built- in rechargeable battery (backup 3-4 Hrs)
-
Complete digital filter to avoid baseline drifting
And interfering from AC, EMC
-
Auto Grid Printing (selectable)
-
Computer connectivity & print on a4 paper
-
100 Patient data storage & transfer
CLM-1206I WITH INTERPRETATION
1206 PC WITH COMPUTER CONNECTIVITY
SPECIFICATION…
Lead
|
Standard 12 leads, 3 channel print and 1 lead display on screen
|
Recording Channel
|
Six channel, 3 channel, Single &Three Channel +R
|
Rhythm Lead
|
Manually Selectable
|
Lead acquisition
|
synchronously 12 leads
|
Data acquisition
|
18bit / 1000Hz
|
Record Mode
|
Manual mode and automatic, mode Filter AC, LP, Muscle ,EMG, Drift Filter’
|
Input Circuit
|
Floating; Protection against Defibrillator & Pacemaker
|
Auditory Alarm
|
Yes
|
Input Impedence =
|
2.5.MO
|
Time constant >
|
3.2s
|
Auto rec time
|
2.5, 5, 10, 20 S
|
Frequency Response
|
0.05~150Hz
|
Noisy Level =
|
15µV
|
Sensitivity valve =
|
20µV
|
Inter-Channel Interference =
|
0.5mm
|
Paper speed
|
5.0, 10.0,12.5, 25 / 50mm/s
|
Sensitivity
|
AUTO, 2,5,5,10,20mm/mV
|
Recording mode
|
Thermal Array printing
|
Paper Specification
|
110mmx20m, roll
|
LCD Display
|
20×2 character LCD, display status
|
Safety classification
|
IEC60601-1 class 1, type CF
|
Power supply AC:
|
110V/220v/85~265V,50/60Hz±1Hz;30VA
|
DC:
|