Product Range

ANAESTHESIA RANGE OF PRODUCTS & ITS ACCESSORIES AUTOCLAVE HOSPITAL HOLLOWARE SUCTION UNITS BABY CARE RUBBER GOODS HOSPITAL FURNITURE SCALES DIAGNOSTIC REHABILITATION AIDS MEDICAL DISPOSABLES HISTOPATHOLOGY LAUNDRY EQUIPMENT OPHTHALMIC INSTRUMENTS BLOOD PRESSURE & PULSE MEASUREMENT MEDICAL EQUIPMENT NON WOVEN SURGICAL INSTRUMENTS VACCUTAINERS TUBE NEBULIZER DELIVERY SET MEDICAL PAPER DIATHERMY MACHINES MEDICAL LIGHT POLYGLACTIN SUTURE ELEECTROLYTE ANALYZER MEDICAL BANDAGES MEDICAL COTTON TESTING EQUIPMENT

CARELABMED MONITOR


CLM 107 CARDIAC MONITORCLM

CARDIAC   MONITORCLM

 

FEATURES

  • 8.4 Color TFT Display
  • Display : Spo2%, pulse rate, ECG all lead
  • Monitor adult, paediatrics and neonates
  • ESU Protected (electric surgical unit) noise
  • Read through motion and low perfusion conditions.
  • Audible visual & vocal alarm
  • Trend: Saturation and Pulse rate memories (24Hrs)
  • Built0in rechargeable Battery

ECG

Lead                          

5 leads (R, L , F , N, C)

 

Wave Form               

7 Channel 1  ; II ; III ; avR ; avF ; V.

 

Wave Speed (mm/s) 

 

12.5/25 /50

Heart Rate range       

0-350 bpm.

 

Alarm range              

0-250 bpm.

 

Accuracy                   

 

2%

Gain Selection                       

X0.5 ; X1 ; X2 ; X4.

 

Lead Fault Alarm                  

audible / Visible

ST Segment / Arrhythmia Analysis  

 

Yes

 


CLM 109 MULTIPARA PATIENT MONITOR

MULTIPARA  PATIENT  MONITOR 

FEATURE  &  SPECIFICATION.

ECG.

Lead                          

User selectable 3 or5 leads (R, L , F , N, C)

 

Lead selection                       

1  ; II ; III ; avR ; avF ; V.

Wave Form               

 

7 Channel

Wave Speed (mm/s) 

12.5/25 /50

 

Heart Rate range       

 

0-350 bpm

Alarm range               

0-250 bpm

Accuracy                   

 

2%

Gain Selection                       

X0.5 ; X1 ; X2 ; X4.

 

Work status               

 

OPE, MON, DIA

Lead Fault Alarm      

audible / Visible

ST segment Check    

Measurement Range : - 1.0 mV ~ + 1.0 Mv

Alarm range                :   0.80 m V ~ 0.80 mV

Arrhythmia Analysis

 

Yes

NIBP

Measure Modal         

 

Auto Surge.

Working Mode  

Auto / Manual

Cycle                             

 

I – 480 min.

Overload Protection  

adult / pediatric/ neonatal.

 

Alarm Range for systolic BP

Diastolic BP & Mean BP

Range

Adult  :  25 -260 mm Hg,

 Child: 25-195 mm Hg

& Infant :  15 – 145 mm Hg

SpO2 –

Compatible with Nellcor technology

Read through motion &

Low perfusion condition.

Measurement  Range            

0-  100%

Alarm  Range                      

0-  100%

Resolution

1%

Pulse Rate

15 to 300 beats per minute.

Respiration.

Respiration Method

IRSP & Nose (Optional)

Measurement range

1 – 99 rpm.

Alarm range

1 – 120 npm

Respiration Scale

X0.5, Xi, X2, X4

Apnea Alarm

Yes.

Power Requirement.

AC Imput

220 V 10% 50 Hz

Internal Battery

4 A / Hr 12V lion.

Battery operation time

            120 min.

Upgradable to etco2 & JBP

  • ECG . Spo2 . NIBP. RESP
  • 8.4 Color TFT display
  • For adult, Pediatric  & Neonatal Usage.
  • Designed by latest digital
  • Read through low Perfusion condition
  • Nellcor compatible Tech
  • Audio/ Visual & vocal Alarm
  • Read through low perfusion condition
  • High filter to avoid drifting and interfering
  • Protect ESU (Electro surgical Unit)
  • Multiple face selection with large font size.
  • Multiple parameter selection
  • Dynamic Trend. ST Analysis Arrthymia Analysis
  • Advanced software for PC interface-CMS

CLM 501 ETCO2 MONITOR WITH PULSE OXIMETER

ETCO2 MONITOR WITH PULSE OXIMETER      

 

Measures : EtCo2  with Capnograph,

Respiration rate, Spo2 with Pleth

& Pulse rate

Model CLM-501 Desktop end tidal Co2 capnograph monitor with pulse oximetry is an extremely useful and comprehensive anaesthetic monitoring device, it can supervise four physical parameters at the same time namely density of EtCO2, respiration, Pulse rate and oxygen saturation. It has a crisp clear wave form with large bright numerical readouts for maximum visibility. It has a user selectable option to view capnograph or plethysmogram waveform simultaneously.

End tidal Co2  (EtoCO2) with capnograph

Measurement range   

0 % - 10 Co2

Units      :   user selectable

mmHg or %

Display range

0 – 100 mmHg or   0-10.0%

Accuracy

±1 % when density of EtCo2 in 0.0---6%

±2 % when density of EtCo2 in 6 –10%

 

Technique

Non dispersive Infra red  absorption

With automatic calibration technology

And moisture removal system

Respiration rate (RR)

Measurement range

0-150bpm

Range

6 times/ min ---60 times/min

Deviation

the bigger value of 2% or 2 times / min

 

Averaging

4 breath average

Oximetry saturation (Spo2) with plethysmogram

Range                                     :       0% - 99%

Accuracy when 50%, 79%±3%  (absolute value)

when 80%,99%,±2% (absolute value)

reads through motion and low perfusion condition.

Perfusion: compatible for adult, pediatric and neonate sensors.

Pulse rate(PR)

Range         :    30bpm – 250bpm

Accuracy    :    ± 2%

Battery Backup     :   One hour

Alarm

User adjustable upper and lower limits for all

EtCo2, resp, Spo2 & pulse rate with audio &

Visual alarm. Apnea alarm : Yes.

Trend

24 hours trend for all parameter :

Etco2, concentration, respiration rate,

Spo2 & pulse.


CLM 703 FOETAL MONITOR

FOETAL  MONITOR    

Features

Wide 5.7 “ color TFT screen.

Digital display and waveform oscilloscope of Twin FHR and TOCO.

Continuous monitoring of twin foetal heart rate and uterine contraction (OP)

Latest uterine contraction probe has the function of arousing the foetus

Built – in high-resolution thermal printer

9 – chip impulse ultrasound transducer,

Highly sensitive, wide scope pressure transducer

Signal intensity indication ensures transducer detecting position.

In – built li-ion battery

Full functional remote control.

SPECIFICATIONS:

Display

5.7” color TFT display

Display

FHR, uterine contraction, FM, date & time

 

Trace

FHR,  Uterine contraction.

 

Paper size

112mm X 100mm X 160P folded

 

Audible & visual alarm  

Yes.

Power

AC -100 ~ 240v,  50/60Hz, 40VA.

Network mode  

Rs485 mode :infinitive extension under TCP/IP mode

 

Built – in li-ion battery works continuously for 3.5 Hrs

Size & weight (L)313 X(W)251mmX(H)94mm. 2.8Kgs.

Twin  foetal heart rate (FHR) Measurement.

Measuring method

pulse ultrasound doppler.

Measuring scope

30~240Bpm

Measuring tolerance

1 BPM

Foetal Heart rate Graphic display scope  

50~240 BPM

Foetal heart rate numeric display scope

50~ 240 BPM

 

Ultrasound working frequency

2.0MHZ

Uterine Contraction Pressure (TOCO) Measurement.

Measuring method

external measurement.

Measuring range

30~240Bpm

Measuring tolerance

1 BPM

Uterine Constriction pressure Graphic display scope  

0~255 BPM

Uterine constriction pressure numeric display scope

0~ 255 BPM

Auto zero function

Yes

TOCO zero points                  

Yes

TOCO zero points

  0,5, 10, 15, 20, 25, 30

Foetal Movement Record (Wireless)

Detect method                        :           manually  marked

Wireless remote control switch

Calculates total foetal movement

Full function remote control.

  • FHR Measurement 
  • Uterine contraction pressure (TOCO) measurement
  • FM record (wireless)
  • Remote

CLM 903 MULTIPARAV PATIENT MONITOR

MULTIPARAV  PATIENT  MONITOR                           

FEATURES  &  SPECIFICATION.

 

  • ECG. HR. Spo2. NIBP. RESP & .2 – Temp
  • Large 12.1 “ TFT Colour display.
  • Latest Digital Nellcor compatible Spo2 Module for high accuracy.
  • For adult, Pediatric & Neonatal Usage.
  • Read through low Perfusion Condition.
  • High filter to avoid drifting and interfering.
  • Protect ESU (Electro Surgical Unit)
  • Drug Dose Calculation, Arrhythmia analysis,
  • ST Analysis.
  • Multiple Face selection with Large font Size.
  • Dynamic Trend.
  • Central monitoring system
  • ECG

    cc

    SpO2

    NellcorCompatibe with extension Cable

    Read through motion & Low perfusion condition.

    Measurement Range                                     

    0-100%

     

    Alarm Range                                                

     

    0-100%

    Respiration.

    Respiration Method                                       .

     

    IRAP

    Measurement range                                      

     

    1

    Alarm Range                                     

    1 -120 bpm

    Accuracy                                                       

    ± 2rpm / 10% whichever is greater.

     

    Respiration Scale                                         

    X0.5, X1+, X2, X4.

     

    Apnea Alarm                                                 .

     

    Yes

    Temperature

    Channel                                                         

    2 with

    Difference indicator

    Alarm Range

    0 – 50° C.

    Resolution

    0.1° C.

    Accuracy

    ± 0.2° C.

    NIBP

    Measure Modal

    Auto Surge.

    Working Mode

    Auto / Manual.

    Cycle time

    1 – 480 min.

    Overload Protection  

    Adult / pediatric / neonatal.

    Alarm Range

    YES

    Range                                                            

    Adult : 25 – 260 mm Hg,

    Child : 25 – 195 mm Hg

    Infant : 15 – 145 mm Hg

     

     

    Power  Requirement.

    AC Input                                                        :   220 V 10% 50Hg

     

    220 V 10% 50Hg                                          :   220 V 10% 50Hg

     

    Internal Battery

    4 A / Hg 12 V lead-

     

    Battery operation time

    120 min.

     

    Upgradable to IBP-2 & ETCo2

     

     

     

     

     


CLM 905 MULTIPARA PAIEN MONITOR WITH FETAL MONITOR

MULTIPARA PAIEN MONITOR WITH FETAL MONITOR

Features  & Specification.

Lead

5 leads (R, L , F , N, C)

Lead selection           

1  ; II ; III ; avR ; avL; avF ; V.

 

Wave Form               

 

7 Channel

Wave Speed (mm/s) 

 

12.5/25 /50

Heart Rate range       

0-350 bpm.

 

Alarm range              

0-250 bpm.

 

Work status               

OPE, MON, DIA

 

Lead Fault Alarm      

audible / Visible.

 

ST segment Check    

Measurement Range : - 1.0 mV ~ + 1.0 mV

Alarm rang :   0.80 m V ~ 0.80 mV

 

 

ECG signal Range

10 (mv) peak to peak value.

Arrhythmia Analysis

Yes

SpO2

Read through motion & Low perfusion condition.

Measurement Range

0-100%

Alarm Range

0-100%

Temperature.

Channel          

2with

Difference indicator

Measurement Range  

0 - 50 C

Alarm range

0 – 45 C.

Power Requirement.

AC  Input

220V 10% 50Hz

Internal Battery

4 A / Hr  12V lead

Battery operation time

120 min.

Respiration.

Measurement range                                      

1 – 99 rpm

 

Alarm range   

1 – 120 bpm

Respiration scale

X0.5, X1, X2, X4.

Apnea Alarm

Yes

NIBP

Working Mode

Auto / Manual

Cycle Time    

1 – 480 min

  • ECG .HR .Spo2 . NIBP. RESP. 2 –Temp
  • Fetal Heart Rate (FHR).UC (TOCO).&FM
  • Large 12.’’ TFT colour display.
  • Integrated modular system and latest digital tech.
  • For Adult, pediatric & Neonatal Usage.
  • Protect ESU (Electro surgical Unit )
  • Drug dose calculation, arrhythmia analysis,
  • ST analysis. Built- in Printer
  • Dynamic trend.
  • Central monitoring system
  • ECG

 


CLM 907 MULTIPARA PATIENT MONITOR

MULTIPARA  PATIENT  MONITORCLM

FEATURES &  SPECIFICATIONS.

Lead

5 leads (R, L , F , N, C)

Lead selection

1  ; II ; III ; avR ; avL; avF ; V.

Wave Form

7 Channel

Wave Speed (mm/s)

12.5/25 /50

Heart Rate range

0-350 bpm

Alarm range

0-250 bpm.

Accuracy

2%

Gain selection

X 0.5 ; X 1 ; X 2; X 4.

Work status

OPE, MON, DIA

Lead Fault Alarm

audible / Visible.

ST segment Check

Yes

Arrhythmia Analysis 

 Yes

 

Pace Maker detection

Yes

 

SpO2

Read through motion & Low perfusion condition.

With extension cable

Measurement Range

0-100%

Alarm Range                                                

0-100%

 

Resolution                                                    

 

1%

NIBP

Measure model          .

 

auto surge

Working mode          

auto / manual.

 

Cycle time                 

1 – 480 min.

 

Overload protection  

adult / pediatric / neonatal.

Alarm range for systolic BP,

Diastolic BP & mean BP.

 

Respiration.

Measurement method

IRSP.

Measurement  range

1 – 99 rpm

Alarm range

1 – 120 rpm

Accuracy

± 2 rpm

Respiration scale

X0.5, X1, ± X2, X4.

Apnea Alarm

Yes

 .Temperature.

Measurement range

0° - 50° C

Alarm range

0 – 45 C.

Resolution                  :       

0.1° C

 

Accuracy        

± 0.2° C

Power Requirement.

AC  Input                                   :   220V 10% 50Hz

Internal Battery                        :    4 A / Hr  12V lead

Battery operation time           :   120 min.

  • ECG .HR .Spo2 . NIBP. RESP. 2 –Temp
  • Large 15” TFT Colour display.
  • Ultra Slim design with wall mounting option
  • Latest digital nellcor compatible spo2 module
  • Audio, visual & vocal alarm
  • For adult, pediatric & Neonatal Usage.
  • Read through low perfusion condition
  • High filter to avoid drifting and interfering
  • ESU protection (electro surgical Unit)
  • Drug dose calculation, Arrhythmia Analysis,
  • Pacemaker detection
  • St analysis
  • Osy CRG display
  • Multiple face selection with large font size.
  • Dynamic trend
  • Central monitoring system
  • ECG

© 2017 CARELABMED. All rights reserved. Creation of SstDesigns