CLM 6004M MACINTOSH BLADES ENGLISH PROFILE
MACINTOSH BLADES ENGLISH PROFILE
The Macintosh laryngoscope blade is one of the most popular blades in use
today. The English profile has a smooth, gentle curve that extends from the
base to the tip and a flange that starts at the lock and continues to the tip,
narrowing gradually.
Size
|
Use
|
Length
|
Code (Shiny)
|
Code (Matt)
|
00
|
Premature
|
70MM
|
6004
|
6004M
|
0
|
Neonatal
|
80MM
|
6005
|
6005M
|
1
|
Infant
|
87MM
|
6006
|
6006M
|
2
|
Child
|
108MM
|
6007
|
6007M
|
3
|
Adult
|
118MM
|
6008
|
6008M
|
4
|
Large Adult
|
128MM
|
6009
|
6009M
|
5
|
Extra Large Adult
|
144MM
|
6010
|
6010M
|
CLM 6015M MILLER BLADES
MILLER BLADES
One of the most popular of the straight blades. The tongue is straight with a
slight upward curve near the tip. In cross section, the flange web and tongue
form a C with the top flattened.
Size
|
Use
|
Length
|
Code (Shiny)
|
Code (Matt)
|
00
|
Premature
|
57MM
|
6015
|
6015M
|
0
|
Neonatal
|
75MM
|
6016
|
6016M
|
0.5
|
Small Infant
|
88MM
|
6014
|
6014M
|
1
|
Infant
|
102MM
|
6017
|
6017M
|
2
|
Child
|
153MM
|
6018
|
6018M
|
3
|
Adult
|
195MM
|
6019
|
6019M
|
4
|
Large Adult
|
205MM
|
6020
|
6020M
|
CLM 6400 MACINTOSH BLADES AMERICAN PROFILE
MACINTOSH BLADES AMERICAN PROFILE
The American profile with a slightly more abrupt curvature and a flange
starting at the lock of the blade and continuing to approximately where
the curvature changes direction then disappearing.
Size
|
Use
|
Length
|
Code
|
0
|
Neonatal
|
80MM
|
6400
|
1
|
Infant
|
87MM
|
6401
|
2
|
Child
|
108MM
|
6402
|
3
|
Adult
|
128MM
|
6403
|
4
|
Large Adult
|
159MM
|
6404
|
CLM 6411 MACINTOSH BLADES ENGLISH PROFILE
MACINTOSH BLADES ENGLISH PROFILE
The Macintosh laryngoscope blade is one of the most popular blades in use
today. The English profile has a smooth, gentle curve that extends from the
base to the tip and a flange that starts at the lock and continues to the tip,
narrowing gradually.
Size
|
Use
|
Length
|
Code
|
00
|
Premature
|
70MM
|
6411
|
0
|
Neonatal
|
80MM
|
6412
|
1
|
Infant
|
92MM
|
6413
|
2
|
Child
|
100MM
|
6414
|
3
|
Adult
|
130MM
|
6415
|
4
|
Large Adult
|
155MM
|
6416
|
5
|
Extra Large Adult
|
178MM
|
6417
|
CLM 6431 MILLER BLADES
MILLER BLADES
One of the most popular of the straight blades. The tongue is straight with a
slight upward curve near the tip. In cross section, the flange web and tongue
form a C with the top flattened.
Size
|
Use
|
Length
|
Code
|
00
|
Premature
|
57MM
|
6431
|
0
|
Neonatal
|
75MM
|
6432
|
1
|
Infant
|
102MM
|
6433
|
2
|
Child
|
153MM
|
6434
|
3
|
Adult
|
195MM
|
6435
|
4
|
Large Adult
|
205MM
|
6436
|
CLM 6705M MACINTOSH BLADES AMERICAN PROFILE
MACINTOSH BLADES AMERICAN PROFILE
The American profile with a slightly more abrupt curvature and a flange
starting at the lock of the blade and continuing to approximately where
the curvature changes direction then disappearing.
Size
|
Use
|
Length
|
Code
|
0
|
Neonatal
|
80MM
|
6705M
|
1
|
Infant
|
87MM
|
6706M
|
2
|
Child
|
108MM
|
6708M
|
2.5
|
Large Child
|
118MM
|
6709M
|
3
|
Adult
|
128MM
|
6710M
|
3.5
|
Medium Adult
|
144MM
|
6711M
|
4
|
Large Adult
|
159MM
|
6712M
|
CLM 6916 MILLER BLADES
MILLER BLADES
One of the most popular of the straight blades. The tongue is straight with a
slight upward curve near the tip. In cross section, the flange web and tongue
form a C with the top flattened.
Size
|
Use
|
Length
|
Code
|
0
|
Neonatal
|
77MM
|
6916
|
1
|
Infant
|
102MM
|
6917
|
2
|
Child
|
153MM
|
6918
|
3
|
Adult
|
195MM
|
6919
|
4
|
Large Adult
|
205MM
|
6920
|
CLM 6956 MACINTOSH BLADES ENGLISH PROFILE
MACINTOSH BLADES ENGLISH PROFILE
The Macintosh laryngoscope blade is one of the most popular blades in use
today. The English profile has a smooth, gentle curve that extends from the
base to the tip and a flange that starts at the lock and continues to the tip,
narrowing gradually.
Size
|
Use
|
Length
|
Code
|
1
|
Infant
|
92MM
|
6956
|
2
|
Child
|
100MM
|
6957
|
3
|
Adult
|
130MM
|
6958
|
4
|
Large Adult
|
155MM
|
6959
|
CLM 6966 MACINTOSH BLADES AMERICAN PROFILE
MACINTOSH BLADES AMERICAN PROFILE
The American profile with a slightly more abrupt curvature and a flange
starting at the lock of the blade and continuing to approximately where
the curvature changes direction then disappearing.
Size
|
Use
|
Length
|
Code
|
1
|
Infant
|
87MM
|
6966
|
2
|
Child
|
108MM
|
6968
|
3
|
Adult
|
128MM
|
6970
|
4
|
Large Adult
|
159MM
|
6972
|
CLM AN LARYNG 6600 ULTRA BRIGHT LED LIGHT SOURCE
ULTRA BRIGHT LED LIGHT SOURCE
Features
• Bright LED Illumination provides White light ensuring true tissue color for accurate
identification of trachea & landmarks.
• Cool White light as compared to heat emitting yellow light bulb.
• Reliable, over 30,000 hours of light output.
• Energy Efficient, low power consumption means longer battery life.
• Compatibility with all disposable, reusable Green System fibre optic blades.
• Economical; a great value when you compare to our competition. The Handle
shown in the picture is sold separately.
CLM 6601 STANDARD HANDLE ACCEPTS TWO SIZE
6601 STANDARD HANDLE
Accepts two size "C" 1.5 V cells
6602 STUBBY HANDLE
Accepts two size "AA" 1.5 V cells
6603 PENLITE HANDLE
Accepts two size "AA" 1.5 V cells
CLM 6722 GREEN SYSTEM BLADES WITH FLEXIBLE ARTICULATING TIP
GREEN SYSTEM BLADES WITH FLEXIBLE ARTICULATING TIP
Size
|
Use
|
Length
|
Code
|
2
|
Child
|
100MM
|
6722
|
3
|
Adult
|
130MM
|
6723
|
4
|
Large Adult
|
155MM
|
6724
|
CLM 6805 MACINTOSH BLADES AMERICAN PROFILE
MACINTOSH BLADES AMERICAN PROFILE
The American profile with a slightly more abrupt curvature and a flange
starting at the lock of the blade and continuing to approximately where
the curvature changes direction then disappearing.
Size
|
Use
|
Length
|
Code
|
0
|
Neonatal
|
80MM
|
6805
|
1
|
Infant
|
87MM
|
6806
|
2
|
Child
|
108MM
|
6808
|
2
|
Large Child
|
118MM
|
6809
|
3
|
Adult
|
128MM
|
6810
|
3.5
|
Medium Adult
|
144MM
|
6811
|
4
|
Large Adult
|
159MM
|
6812
|
CLM 6716 MILLER BLADES
MILLER BLADES
One of the most popular of the straight blades. The tongue is straight with a
slight upward curve near the tip. In cross section, the flange web and tongue
form a C with the top flattened.
Size
|
Use
|
Length
|
Code
|
0
|
Neonatal
|
77MM
|
6716
|
1
|
Infant
|
102MM
|
6717
|
2
|
Child
|
153MM
|
6718
|
3
|
Adult
|
195MM
|
6719
|
4
|
Large Adult
|
205MM
|
6720
|
CLM 6906 MACINTOSH BLADES ENGLISH PROFILE
MACINTOSH BLADES ENGLISH PROFILE
The Macintosh laryngoscope blade is one of the most popular blades in use
today. The English profile has a smooth, gentle curve that extends from the
base to the tip and a flange that starts at the lock and continues to the tip,
narrowing gradually.
Size
|
Use
|
Length
|
Code
|
1
|
Infant
|
92MM
|
6906
|
2
|
Child
|
100MM
|
6907
|
3
|
Adult
|
130MM
|
6908
|
4
|
Large Adult
|
155MM
|
6909
|
5
|
Extra large Adult
|
178MM
|
6910
|
CLM AN LARYNG 6521 BLADES WITH FLEXIBLE ARTICULATING TIP
BLADES WITH FLEXIBLE ARTICULATING TIP
Features
• Articulating tip provides precise control to elevate the epiglottis
• Channel to help visualize the epiglottis & facilitate the insertion of an E/T Tube
• Unobstructed View
• Unique anti-seize spring action
• Optimal smooth action
• Precision made for ruggedness & high quality
• Full Stainless Steel construction
• Conventional Lamp type
• Fits on all Hook-on Handles
• Unbeatable Value for money - every private practicing anaesthesiologist, nursing
home & hospital can afford to buy.
The Handle shown in the picture is sold separately. There is no need to purchase any
extra or special handle, as your existing hook-on handle can be used.
CLM 6072 POUCH
POUCH
Pouch for Laryngoscope Set
CLM AN LARYNG 6175 HOWLAND LOCK
HOWLAND LOCK
Most laryngoscope blades form a 90 angle with handle when ready for use.
When a Howland lock is fitted between the handle and the blade by means
of Hook-on connections on both ends, it forms a 450 angle. This change in
the angle helps natural lifting action which simplifies natural exposure making
intubation possible in the most difficult of cases.
The Handle & Blade shown in the picture are sold separately
CLM 6001 STUBBY HANDLE
STUBBY HANDLE
Useful during difficult intubation on a short neck, barrel chested or large bosomed patient where the distance between the mouth
& the chest restricts the use of a standard handle. Stubby acceptstwosize“A A” 1.5 volts cells.