CARELABMED FRONT LOADING FLASH STERILIZER
Salient Feature:
-
Table top front loading autoclave.
-
Fully automatic micro-processor based control.
-
Sterilization chamber made up of thick stainless steel sheet, tested for high pressure.
-
Digital timer both for wet & dry cycle.
-
Auto drain of water to reservoir tank & also condensation.
-
Alarm after the total command is completed.
-
Cycle time 10-15 mins.
Technical specification:-
|
Model
|
CLM-AU-17-FL
|
Capacity
|
17 Lts
|
Chamber dimensions
|
230 x 410 mm
|
Construction chamber
|
SS 304
|
Power consumption
|
1.5 Kw
|
Operating pressure
|
1.2-2. 1kg/cm 2
|
Timer
|
0-99 min
|
Operating temperature
|
121`c-134`c
|
Voltage
|
230V
|
Control
|
Digital
|
Gross weight
|
60 kg
|
Shipping size (mm)
|
580 x 600 x 430
|
Pre-vacuum(Air Removal System)
Vacuum turbo clave brings to a perfect sterilizer action because the vacuum pump of a large power does an entire elimination of air in sterilizer room before the heating and then heating sterilizer in a vacuum.
Post-vacuum (Dry System)
Our vacuum pump of large power is operated an automatically inhalation and exhalation for stem in sterilizer room so that Vacuum TURBO Claves raises more drying ability than its competitors.
Vacuum Test
Vacuum Turbo Caves has a function of finding problems of machine by testing airtight condition of sterilizer room and is designed to can the operate a best condition
Bowie-Dick Test
When we confirm to packs specimens after sterilizer, Vacuum Turbo Clave true the perfect sterilizer efficiency. It will be able to confirm a sterilizer efficiency at least time and is designed to be easy the examining possibilityto a user.
Bacteria Filter
Bacteria Filter
Vacuum Turbo Clave is applied an air filter which filrates99.9 % 0.3 micron particles and suppresses bacteria.
Recoder Printer
Vacuum Turbo Clave can print out all reports ,sterilizer pressure, sterilizer temperature, sterilizer time ,and dry time etc, with year/month/hour/Error Message.
Graphic LCD Monitor
Graphic LCD Monitor indicates various information sterilizer pressures, sterilizer time, dry time, water level and error Message under the operation.
Auto Process
Auto process indicates this progress order of condition (vacuum> water supplying >heating),sterilizer (sterilization exhaust),Dry, End, Fail (error or shut down).
Mode select
Package programs as the sterilizer pack set in sterilizer pack set in sterilization set in sterilization temperature: 134`C,Sterilization time : 20 minutes & dry time:20 minutes
Instrument program as devices of metal type set sterilization temperature:134`C,sterilization time:10 minutes & dry time: 20 minutes.
Ruber programs as device of rubber type & plastic type for sterilization set in sterilization
Temperature:121`C,sterilization time:30 minute & dry time: 20 minutes.
Manual program
Manual program as the user setting program set in sterilization temperature : 121`C – 135` C, sterilization time: 1- 60 minutes & dry time: 1 – 60 minutes.
Dry Program
If you want only drying, you drying 1 to 60 min dry program.
Error Code
If it is affected some problem for sterilization process,.Error codes one of 13 Error code to Graphic LCD monitor. It is automatically running depended on Micro processer & has a self test function.