CARELABMED OXYGEN THERAPY EQUIPMENTS

CLM/AN/OTE/OR/1175

#

CARELABMED OXYGEN REGULATOR WITH FLOW GAUGE

Description:
• Replacement of The Flowment Of The Flowmeter Unit By A Flow Gauge With Gauge Saver And A Rugged All Metal Construction Ensures Less Frequent & Reduced Maintenance / Serving. Tamper-proof Safety Blow Off Situated Inside The Regulator Prevents Unauthorized Adjustment of Blow Off Pressure Large Control Knob Provides More Convenient
Operation.

Send Enquiry

CLM/AN/OTE/OR/1176

#

CARELABMED OXYGEN REGULATOR

Description:
• The Rugulator has A factory Present Fixed Static Outlet Pressure Of Approx. 4.2 Kg/Sq.Cm (60 lbs/sqin) And Is fitted with safety valve. Once the flowrate has been set the regulator will automatically maintain a constant floe rate irrespective of changing volume of cylinder contents.
If the oxygen line distal to the regulaor should be blocked the regulator automatically prevent the build up of an excessive pressure the build up of an excessive pressure in the apparatus and tubing between the outlet of the regulator and the obstruction. A pressure gauge indicates the cylinder contents.

Send Enquiry

CLM/AN/OTE/OR/1178

#

CARELABMED TWO STAGE OXYGEN REGULATOR

Description:
• Two stage regulator it has two disphragms where by provides extra safety in case of damage to one of the Diaphragm. It has an extra gauge to indicate outlet pressure.

Send Enquiry

CLM/AN/OTE/FU/1190

#

CARELABMED FLOWMATER UNIT

Description:
• Metar and plastic the back pressure compensated (BPC) flowmeter incorporates a rotary pin valve control to permit adjustment of the flow rate to any desired level between 0 – 15 ltrs/min. jacketed type shatter proof tubes are fitted on the units the outlet at the bottom of the unit is fitted with a removable nipple. After removing the outlet nipple, a humidifier can be screwed into the outlet of the flowmeter unit. Flow accuracy is unaffected by back pressure due to down stream restrictions caused by humidifiers, nebulizers etc.

Send Enquiry

CLM/AN/OTE/FU/1179

#

CARELABMED F/A (FINE ADJUSTMENT) VALVE WITH GAUGE & FLOWMETER

Description:
• Set comprises of F/A valve with gauge flowmeter & hauge saver the unit reduces the cylinder pressure by merely providing a variable restriction to the flow of oxygen from the cylinder outlet. As volume of oxygen in the cylinder reduces, the flowmeter has to be constantly adjusted type shatter proof tubes calibrated from 0-15 litrs/min.
Note : The flowmeter without control used in the F/A valve should not be used with an oxygen regulator.

Send Enquiry

CLM/AN/OTE/HU/1195

#

CARELABMED HUMIDIFIERS

DISCRIPTION
• Consists of an unbreakable jar with screw on cap fitted on top inlet and side outlet tubes. The inlet tube ends in a specially designed diffuser from which oxygen is bubbled through water before reaching the outlet

PRODUCT CODEFEATURE
CLM/AN/OTE/HU/1195 HUMIDIFIERS WITH ‘S HOOK – FOR HANGING ON THE CYLINDER TROLLEY OR FLOWMETER UNIT
Send Enquiry

CLM/AN/OTE/HU/1196

#

CARELABMED HUMIDIFIERS

Description:
• Consists of an unbreakable jar with screw on cap fitted on top inlet and side outlet tubes. The inlet tube ends in a specially designed diffuser from which oxygen is bubbled through water before reaching the outlet.

PRODUCT CODEFEATURE
CLM/AN/OTE/HU/1196 HUMIDIFIER – SCREW ON TYPE – PLASTIC INLET PROVIDED WITH 1/2” BSF THREADS THAT CAN BE SCREWED ON DIECTLY TO THE OUTLET OF THE FLOWMETER
Send Enquiry

CLM/OTE/HU/1197

#

CARELABMED HUMIDIFIERS

Description:
• Consists of an unbreakable jar with screw on cap fitted on top inlet and side outlet tubes. The inlet tube ends in a specially designed diffuser from which oxygen is bubbled through water before reaching the outlet.

PRODUCT CODEFEATURE
CLM/OTE/HU/1197 – HUMIDIFIER – FOR GENERATOR – PLASTIC INLET HAS A 9/16 UNF FEMALE KNURLED NUT & NIPPLE AT THE INLET
Send Enquiry

CLM/AN/OTE/HU/1198

#

CARELABMED HUMIDIFIER WITH RELIEF VALVE

Description: 
• Oxygen humidifier provides high humidity to oxygen using the bubble-type humidificaton process it contains a 3-psi safety relief valve. The outlet fitting is a hose barb for 6mm Id plastic tubing. Max and min. water levels are clearely market the max line hold 100 ml of water

PRODUCT CODEFEATURE
CLM/AN/OTE/HU/1198 HUMIDIFIER  - SCREW ON TYPE
Send Enquiry

CLM/AN/OTE/HU/1199

#

CARELABMED HUMIDIFIER WITH RELIEF VALVE

Description: 
• Oxygen humidifier provides high humidity to oxygen using the bubble-type humidificaton process it contains a 3-psi safety relief valve. The outlet fitting is a hose barb for 6mm Id plastic tubing. Max and min. water levels are clearely market the max line hold 100 ml of water

PRODUCT CODEFEATURE
CLM/AN/OTE/HU/1199 HUMIDIFIER – FOR GENERATOR
Send Enquiry

CLM/AN/OTE/HU/1200

#

CARELABMED HUMIDIFIER WITH RELIEF VALVE ALL PLASTIC

PRODUCT CODEFEATURE
CLM/AN/OTE/HU/1200 HUMIDIFIER – FOR GENERATOR
Send Enquiry

CLM/AN/OTE/1191

#

CARELABMED VENTILATOR FOR BRONCHOSCOPY

Description:
• A ventilating system for rigid wall bronchoscopy and laryngeal microsurgery. Comprises : 2mtrs, high pressure tubing, thumb valve control and three luer lock needles.

Send Enquiry

CLM/AN/OTE/OR/1180

#

CARELABMED TWIN GAUGE OXYGEN REGULATOR

Description:
• Specially introduced for use with the jet ventilator and other application it has an extra gauge to indicate the outlet pressure of the regulator and incorporates a safety valve. The outlet pressure of the regulator and incorporates a safety valve. The outlet pressure can be adjusted with the help of the key to desired value depending upon use for paediatric or adult patients.

Send Enquiry

CLM/AN/OTE/OR/1181

#

CARELABMED AIR REGULATOR

Description:
• The regulator has a factory preset fixed static outlet pressure of approx. 4.2 Kg/Sq.cm and is fitted with safety valve. Once the flow rate has been set the regulator will automatically maintain a constant flow rate Irrespective of changing volume of cylinder contents. A pressure gauge indicates the cylinder contents.

Send Enquiry

CLM/AN/OTE/OR/1182

#

CARELABMED NITROUS OXIDE REGULATOR

Description:
• Nitrous oxide regulators have bright chrome plated forged brass body that ensures long life and corrosion resistance of these products.

Technical detail:
• 2” Diameter Gauge With Gauge Guard
• factory Preset At 4.2 Kg/Cm
• Built In Safety Valve to Protect Against Over Pressurization
• Durable Neoprene Diaphragm

Send Enquiry

CLM/AN/OTE/1183

#

CARELABMED TWIN FLOWMETER ADAPTOR

Description:
• For Using Two BPC Flowmeters From one oxygen regulator

Send Enquiry

CLM/AN/OTE/1184

#

CARELABMED SPANNERS & KEYS

PRODUCT CODEFEATURE
CLM/AN/OTE/1184Combination Key & Spanner – for fitting regulators & F/A valves onto cylinders and for opening bull nose type cylinder. Cannot be used to open pin index type cylinders 
Send Enquiry

CLM/AN/OTE/1185

#

CARELABMED SPANNERS & KEYS

PRODUCT CODEFEATURE
CLM/AN/OTE/1185Multipurpose – for fitting flowmeters onto F/A Valves or regulators. Hex nuts onto bull nose type & flush type cylinders & for opening and closing both bull nose type as well as pin index type cylinder 
Send Enquiry

CLM/AN/OTE/1186

#

CARELABMED SPANNERS & KEYS

PRODUCT CODEFEATURE
CLM/AN/OTE/1186-key for pin index cylinder – for opening pin index type cylinders & fitting hex nuts to the valves 
Send Enquiry

CLM/AN/OTE/1210

#

CARELABMED OXYGEN NASAL CANNULA (DISPOSABLE)

Description:
• Adult
• Child
• Neonatal
• Not Just Another Oxygen nasal cannula – the ‘U` shaped moulding with limbs which is inserted into the nostrils will not hurt the patient when inserted.
• Extremely light in weight, the nasal tips ensure a comfortable fit for efficient oxygen therapy. Supplied with 2 meters tubing.

Send Enquiry

CLM/AN/OTE/1211

#

CARELABMED OXYGEN MASK – PLAIN (DISPOSABLE)

Description:
• Adult
• Child
• Light Weight design, soft feathered edges for increased patient comfort, nose clip for nose bridge adjustment & for better fit,   pull through adjustable elastic head band & swivel tubing connector for changing angle of operation without head band & swivel tubing connector for changing angle of operation without disturbing the mask.

Send Enquiry

CLM/AN/OTE/1213

#

CARELABMED OXYGEN MASK WITH % CONTROL (DISPOSABLE

Description:
• Adult
• child
• one piece adjustable venture valve with a choice of seven oxygen percentage setting (24, 26, 28, 31, 35, 40, & 45%) Allowing the concentration of oxygen delivered to the patient to be set and changed as clinically as is required. Eliminates use of several selector venture valves thus significantly reducing the time required to change oxygen concentration.

Send Enquiry

CLM/AN/OTE/1213

#

CARELABMED HIGH CONCENTRATION MASK (DISPOSABLE)

Description:
• Adult
• Child
• High concentration oxygen mask is used to deliver 100% oxygen to patient.
• There is a two litre reservoir bag with 3 one-way valves to deliver 100% oxygen.
• Two expiratory valves are easily detachable as per the need of the patients.

Send Enquiry

CLM/AN/OTE/1214

#

CARELABMED OXYGEN MASK WITH NEBULISER (DISPOSABLE

Description:
• Adult
• Child
• Set comprises of plain oxygen mask nebulizer jar & tubing. The nebulizer jar is specially designed for the delivery of drugs for tracheobronchial deposition. At gas flow of 8 l/min, 70% of output will be particles of less then 5 microns.

Send Enquiry

CLM/AN/OTE/1215

#

CARELABMED NEBULISER MOUTH KIT

Description:
Mouthpiece is particularly usefull for patient who can coordinate their breathing for drug delivery, thereby increasing the amount of aerosol reaching the lungs.