I.V Cannula with Injection on Port & Wings with Safety
Features:
**Sizes : 14G to 26G**
• The highly polished stainless-steel needle with a triple-faceted back cut reduces penetration force and minimizes the risk of nerve damage.
• Bio-compatible material for longer indwelling period
• Flexible wings for secure fixation.
• Excellent needle sharpness/catheter tipping for less traumatic insertion.
• Passive device for protection from needle stick injury.Needle sharp tip is locked inside a plastic safety guard after use.
• The safety guard is designed to enclose needle sharp tip after the needle is withdrawn hence preventing healthcare professionals from the risk of
accidental needle stick injury.
Available in:
• FEP/PTFE/PUR Catheter
• IV Cannula without Wings & without Port with safety Feature
• IV Cannula with Wings & without Port with safety Feature
• Packaging - Blister Pack
Gauge | Catheter OD(mm) | Catheter Length(mm) | Flow Rate (ml/min.) | Packaging (inner/outer) |
14G | 2.1 | 45 | 300 | 100/1000 , 50/500 |
16G | 1.8 | 45 | 200 | 100/1000 , 50/500 |
17G | 1.5 | 45 | 140 | 100/1000 , 50/500 |
18G | 1.3 | 45 | 90 | 100/1000 , 50/500 |
20G | 1.1 | 32 | 61 | 100/1000 , 50/500 |
22G | 0.9 | 25 | 36 | 100/1000 , 50/500 |
24G | 0.7 | 19 | 19 | 100/1000 , 50/500 |
26G | 0.6 | 19 | 16 | 100/1000 , 50/500 |
Features :
• The highly polished stainless-steel needle with a triple-faceted back cut reduces penetration force and minimizes the risk of nerve damage.
• A siliconized tip for reduced trauma, and improved flow rates and chemical resistance.
• Flexible wings for secure fixation.
• Excellent needle sharpness/catheter tipping for less traumatic insertion.
• Translucent flashback chamber for confirming proper needle placement.
Available in :
• FEP, PUR, and PTFE catheter with or without radiopaque lines.
• Available in Suturable Wing and Flip type Port Cap.
• With or without porous filter in flashback chamber
Gauge | Catheter OD(mm) | Catheter Length(mm) | Flow Rate (ml/min.) | Packaging (inner/outer) |
14G | 2.1 | 45 | 300 | 100/1000 |
16G | 1.8 | 45 | 200 | 100/1000 |
17G | 1.5 | 45 | 140 | 100/1000 |
18G | 1.3 | 45 | 90 | 100/1000 |
20G | 1.1 | 32 | 61 | 100/1000 |
22G | 0.9 | 25 | 36 | 100/1000 |
24G | 0.7 | 19 | 19 | 100/1000 |
26G | 0.6 | 19 | 16 | 100/1000 |
Features :
• The highly polished stainless-steel needle with a triple-faceted back cut reduces penetration force and minimizes the risk of nerve damage.
• A siliconized tip for reduced trauma, and improved flow rates and chemical resistance.
• Flexible wings for secure fixation.
• Excellent needle sharpness/catheter tipping for less traumatic insertion.
• Translucent flashback chamber for confirming proper needle placement.
Available in :
• FEP, PUR, and PTFE catheter with or without radiopaque lines.
• Available in Suturable Wing and Flip type Port Cap.
• With or without porous filter in flashback chamber
Gauge | Catheter OD(mm) | Catheter Length(mm) | Flow Rate (ml/min.) | Packaging (inner/outer) |
14G | 2.1 | 45 | 300 | 100/1000 |
16G | 1.8 | 45 | 200 | 100/1000 |
17G | 1.5 | 45 | 140 | 100/1000 |
18G | 1.3 | 45 | 90 | 100/1000 |
20G | 1.1 | 32 | 61 | 100/1000 |
22G | 0.9 | 25 | 36 | 100/1000 |
24G | 0.7 | 19 | 19 | 100/1000 |
26G | 0.6 | 19 | 16 | 100/1000 |
Features :
• The highly polished stainless-steel needle with a triple-faceted back cut reduces penetration force and minimizes the risk of nerve damage.
• A siliconized tip for reduced trauma, and improved flow rates and chemical resistance.
• Flexible wings for secure fixation.
• Excellent needle sharpness/catheter tipping for less traumatic insertion.
• Translucent flashback chamber for confirming proper needle placement.
Available in :
• FEP, PUR, and PTFE catheter with or without radiopaque lines.
• Available in Suturable Wing and Flip type Port Cap.
• With or without porous filter in flashback chamber
Gauge | Catheter OD(mm) | Catheter Length(mm) | Flow Rate (ml/min.) | Packaging (inner/outer) |
14G | 2.1 | 45 | 300 | 100/1000 |
16G | 1.8 | 45 | 200 | 100/1000 |
17G | 1.5 | 45 | 140 | 100/1000 |
18G | 1.3 | 45 | 90 | 100/1000 |
20G | 1.1 | 32 | 61 | 100/1000 |
22G | 0.9 | 25 | 36 | 100/1000 |
24G | 0.7 | 19 | 19 | 100/1000 |
26G | 0.6 | 19 | 16 | 100/1000 |
Sizes : 18G to 24G
Features :
• Excellent needle sharpness/catheter tipping for less traumatic insertion.
• A siliconized tip for reduced trauma, and improved flow rates and chemical resistance.
• Flexible wings for secure fixation.
• Made using biocompatible material for longer indwelling periods.
• Translucent flashback chamber for confirming proper needle placement.
Available in :
• FEP /PTFE/ PUR Radiopaque Catheter, Hydrophobic Filter
• Packaging : Blister pack
Gauge | Catheter OD(mm) | Catheter Length(mm) | Flow Rate (ml/min.) | Packaging (inner/outer) |
14G | 2.1 | 45 | 300 | 100/1000 |
16G | 1.8 | 45 | 200 | 100/1000 |
17G | 1.5 | 45 | 140 | 100/1000 |
18G | 1.3 | 45 | 90 | 100/1000 |
20G | 1.1 | 32 | 61 | 100/1000 |
22G | 0.9 | 25 | 36 | 100/1000 |
24G | 0.7 | 19 | 19 | 100/1000 |
Sizes : 24G to 26G
Features :
• Excellent needle sharpness/catheter tipping for less traumatic insertion.
• A siliconized tip for reduced trauma, and improved flow rates and chemical resistance.
• Flexible wings for secure fixation.
• Made using biocompatible material for longer indwelling periods.
• Translucent flashback chamber for confirming proper needle placement.
Available in :
• FEP /PTFE/ PUR Radiopaque Catheter, Hydrophobic Filter
• Packaging : Blister pack
Gauge | Catheter OD(mm) | Catheter Length(mm) | Flow Rate (ml/min.) | Packaging (inner/outer) |
24G | 0.7 | 19 | 19 | 100/1000 |
26G | 0.6 | 19 | 16 | 100/1000 |
Sizes : 14G to 26G
Features :
• Excellent needle sharpness/catheter tipping for less traumatic insertion.
• A siliconized tip for reduced trauma, and improved flow rates and chemical resistance.
• Flexible wings for secure fixation.
• Made using biocompatible material for longer indwelling periods.
• Translucent flashback chamber for confirming proper needle placement.
Available in :
• FEP /PTFE/ PUR Radiopaque Catheter, Hydrophobic Filter
• Packaging : Blister pack
Gauge | Catheter OD(mm) | Catheter Length(mm) | Flow Rate (ml/min.) | Packaging (inner/outer) |
14G | 2.1 | 45 | 300 | 100/1000 |
16G | 1.8 | 45 | 200 | 100/1000 |
17G | 1.5 | 45 | 140 | 100/1000 |
18G | 1.3 | 45 | 90 | 100/1000 |
20G | 1.1 | 32 | 61 | 100/1000 |
22G | 0.9 | 25 | 36 | 100/1000 |
24G | 0.7 | 19 | 19 | 100/1000 |
26G | 0.6 | 19 | 16 | 100/1000 |
Sizes : Red , Blue , and White
Features :
• Crystal clear transparent channel.
• Arrows marks on the tap indicate direction of flow.
• Minimum priming volume required for accurate drug administration.
• Connectors meets 6% taper requirement to ensure leakage free fitment.
Available in :
• Universal Color Coding of tap/handle (Red, Blue & White)
• Lipid Resistant.
• Individual Blister Pack (Inner :50 Pack, Outer :500 /1000Pack)
Sizes : 10cm to 250cm
Features :
• Three way stopcock at one end and Male Luer connector at the another end.
• Crystal clear transparent channel.
• Arrows marks on the tap indicate direction of flow.
• Minimum priming volume required for accurate drug administration.
• Connectors meets 6% taper requirement to ensure leakage free fitment.
Available in :
• DEHP Free PVC tube, Lipid resistant
• Individual Pouch pack ( Inner : 25 Pack, Outer : 500 Pack)
Extension Line ( Low Pressure & High Pressure)
Sizes : 10cm to 250cm
Features :
• Kink-resistant PVC tubing.
• Male luer lock at one end and female luer lock at the other end.
• Extension tubes are available in various lengths to accommodate diverse patient needs and medical procedures.
• Extension tubes come with connectors at each end, designed for connection to various medical devices, such as catheters,
• IV lines, syringes, and infusion pumps.
• Transparent extension tubes are designed to allow healthcare providers to easily monitor fluid flow.
Available in :
• DEHP Free PVC tube
• Low pressure monitoring extension line.
• High pressure monitoring extension line
• Individual Pouch pack ( Inner : 25 Pack, Outer : 500 Pack)
Features :
• A fine filter within the chamber offers high flow rates and safeguards against large particles.
• Soft and kink resistant PVC tubing ensures uniform flow rate.
• Smooth roller clamp facilitates easy, safe control and adjustment of fluid rates.
• Suitable for gravity feed as well as pressure infusions up to 2 bars.
Available in :
• With or without vented and non-vented spike.
• With or without needle•
• With Injection Y-site and Male Luer.•
• DEHP-free PVC tubing
• Individual Pouch pack ( Inner : 25 Pack, Outer : 500 Pack)
Features :
• Transparent & calibrated drip chamber.
• Kink resistant PVC tubing.
• Approximately 60 drops/ml.
• Suitable for infusion of measured volume of I V fluid.
• Bacteria retentive air inlet to prevent air contamination.
• Latex Injection port for extra medication.
Available in :
• 110 ml & 150 Ml Drop rate – 60 drops/ml.
• Individual Pouch pack ( Inner : 10 Pack, Outer : 250 Pack)
Features :
• Transparent & flexible drip chamber.
• With 200-micron blood filter.
• Available with priming filter.
• Soft and kink resistant PVC tubing ensures uniform flow rate.
• Smooth roller clamp facilitates easy, safe control and adjustment of fluid rates
Available in :
• With or without vented and non-vented spike.
• With or without needle•
• With Injection Y-site and Male Luer.•
• DEHP-free PVC tubing
• Individual Pouch pack ( Inner : 25 Pack, Outer : 500 Pack)